if you have any question? Call Us 0086-371-60922096

Steam Boiler Automatic Water Feeder

VXT 24 & 120 Residential Steam Water Feeders | Hydrolevel

24 VAC. 120 VAC. Upon a feed signal from low water cut-off, the VXT feeder delays (from 30 seconds to 10 minutes) to allow condensate to return to boiler. If make-upwater is required after the delay period, the VXT will initiate a feed cycle. TheVXT can be set to feed to the level of the low water cut-off or can be set from 1 to 5 gallons to

Get a Quote

Hydrolevel VXT-120 15VA Steam Boiler Automatic Water Feeder

Model Number: VXT120. In addition to this added convenience, The VXT is the first automatic steam boiler water feeder designed to monitor the amount of water added to a steam boiler. Excessive boiler make-up water can cause cast iron boilers to …

Get a Quote

VXT-120 Hydrolevel Water Feeder Makes Loud Screech When

Mar 07, 2018 · This newly installed VXT-120 Hydrolevel automatic water feeder for steam boiler makes an unearthly screech when it feeds. The domestic water pressure was checked and found to be less than 65 psi. The earlier models of feeders never made this noise when feeding.

Get a Quote

Hydrolevel 4567 Water Feeder 24 VAC for Steam Boilers Part

This water feeder is for steam boilers. It can install 2 ports on SS, KS-1U, KS-1H, and KS-2. It has a 24V two speed motor. The Hydrolevel 4567 steam boiler 24-V water feeder replaces part numbers 45-025, 45-016, 45-017 and 45-032. It provides trouble-free operation by delivering water to the steam valves at the proper rate and pressure.

Get a Quote

Automatic Boiler Blow Down System – Volfram Systems

Manual Blow down. If we monitor the TDS Automatic Boiler Blow Down System levels of boiler water online 24 X 7 & do the blow down if necessary & required quantity only then we can: Save fuel by optimizing the blow down quantity. Save fresh Water charges & its chemical treatment cost. Reduce the load on the ETP. Avoid Foaming & Moisture Carry Over.

Get a Quote

The Peril of Automatic Water Feeders - G.W. Gill Plumbing

New boiler prices: What's the real cost of a new boiler?

Get a Quote

We installed a new steam boiler. the automatic water feeder…

Nov 16, 2011 · The steam boiler at my church is not operating properly. The low water cut off unit (lwcu)and automatic feed unit(afu) are malfunctioniing. The lwcu is sending the signal for low water, but the supply … read more

Get a Quote

Home | Hydrolevel

Home | Hydrolevel. Home Administrator KefidT12:23:26-04:00. Introducing the Hydrostat IC, our new 5 in 1 Control for Atmospheric and Induced Draft Gas Boilers! LEARN MORE VXT: The Automatic Water Feeder you can Count On! LEARN MORE Bring out the best in your Slant/ Fin Application with Hydrolevel! Other Controls and Products!

Get a Quote

Hydrolevel 4566 VXT120 Automatic Water Feeder for steam

This automatic water feeder is for use on steam boilers with digital controls. It attaches directly to a supply line and automatically delivers hot water when a building's hot water demand exceeds the boiler's output. The Water Feeder VXT120 Automatic for steam boilers is …

Get a Quote

Ten reasons steam-heating boilers flood - Xylem Applied Water

May 20, 2015 · Modern boilers make steam quickly . If the piping around the boiler is wrong, the boiler throws water into the piping. The automatic water feeder then replaces that water—and before long, the boiler is flooded. Take the time to check the piping on the job against what the boiler manufacturer calls for.

Get a Quote

boiler water feeder | eBay

Hydrolevel 4566 VXT120 Automatic Water Feeder for steam boiler 120V 5.0 out of 5 stars. 1 product rating - Hydrolevel 4566 VXT120 Automatic Water Feeder for steam boiler 120V

Get a Quote

Water feeders and new steam boilers - FIA, Inc

ic water feeder. Perhaps the salesman who sold the job explains to the custom-er that new, efficient steam boilers need feeders to produce enough steam to heat the house. This sounds logical to the ho-meowner (who, by the way, does not un-derstand steam systems), and so an automatic water feeder is installed. Now the boiler runs longer

Get a Quote

HydroLevel VXT120 Automatic Water Feeder for steam boiler

The VXT can be used with virtually any probe or float type low water cut-off; Digital Feed Counter. Displays the amount of water added to the boiler, essential in detecting boiler destroying water loss problems; Programmable Feed Delay. Helps prevent flooded boilers by allowing time for condensate to return to boiler before initiating a feed cycle

Get a Quote

Automatic Water Feeder Install Questions on Steam Boiler

I recently had a VXT-24 automatic water feeder installed on our steam boiler and am wondering if the top ball valve in the picture should close fully 90 degrees (it won't turn anymore than shown and I don't want to force it)? I have it set up to bypass in the picture.

Get a Quote

Water feeders and new steam boilers - FIA, Inc

ic water feeder. Perhaps the salesman who sold the job explains to the custom-er that new, efficient steam boilers need feeders to produce enough steam to heat the house. This sounds logical to the ho-meowner (who, by the way, does not un-derstand steam systems), and so an automatic water feeder is installed. Now the boiler runs longer

Get a Quote

10t Steam Boiler High Efficiency

Steam boiler UL-S - world's best selling Bosch boiler. Universal steam boiler UL-S, UL-SX. The UL-S is a highly efficient steam boiler with a three-pass design for 1,250 to 28,000 kg/h of steam at up to 30 bar. With impressively low emissions and its ability to be converted for biofuels or hydrogen, the UL-S is designed to be future-proof.

Get a Quote

Reasons why steam boiler water level too high and

Jul 22, 2015 · Reasons: The steam boiler's water line is surging. Dirty water, a too-high pH, overfiring and improper near-boiler piping can all cause the steam boiler's water line to surge up and down. If there's an automatic water feeder on the boiler, it will open and close each time the water line rocks.

Get a Quote

Programmable Water Feeder for PROGRAMMABLE FEED …

water automatically. Boilers with float-type cut-offs: 1. With power to the system on and the thermostat off, lower the water level until 1/4" is visible in the gauge glass. 2. Press the FEED button on the water feeder and, using a watch with a second hand, time how long it takes boiler water to reach the normal operating level (Usually the

Get a Quote

169400 McDonnell & Miller Water Feeder 101A | National

Description. 169400 McDonnell & Miller Water Feeder 101A-120v. McDonnell & Miller 101-A Electric Water Feeder Instruction Manual. Electric Water Feeder Features: For low pressure steam boilers with cold water feed. Eliminates necessity to manually add water to the boiler. Can be used with mechanical or electronic low water cut-off controls.

Get a Quote

Boiler / automatic water feeder quick questions

Boiler / automatic water feeder quick questions. Hi r/homeimprovement. I live in a rental and I have a (hopefully) simple question regarding my home's boiler and automatic water feeder. I'm not normally this helpless, but I've never lived in a home with this type of heating system. I'm still working on understanding it.

Get a Quote

Weil-Mclain Steam boiler water feeder issues (VXT

Mar 12, 2014 · Boilers - Home Heating Steam and Hot Water Systems - Weil-Mclain Steam boiler water feeder issues (VXT) - I have a Weil-Mclain PEG 35 gas furnace in a rental and unless I use the manual switch to add water it will not do so by itself. After I add water it works fine until it has no more water. One radiator has a

Get a Quote

Automatic Level Control Systems - Spirax Sarco

The most common method of level control is simply to start the feedpump at a low level and allow it to run until a higher water level is reached within the boiler. With a float level control, a magnetic switch with a built-in hysteresis or dead-band will be used. With conductivity probes, two probes are necessary, (pump on and pump off) which

Get a Quote

Programmable Water Feeder for PROGRAMMABLE FEED …

Programmable Water Feeder for Steam Boilers 24VACOperatingVoltage PatentPending INSTALLATION ModelVXT-24 WARNING –To preventelectrical shockorequipment damage,power

Get a Quote

VXT-120 Programmable Steam Water Feeder for Oil Boiler 45

The VXT is the first automatic steam boiler water feeder designed to monitor the amount of water added to a steam boiler. The addition of make-up water raises the oxygen level in a boiler and accumulates lime and other mineral deposits. Excessive boiler make-up water can cause cast iron boilers to rust internally, severely shortening the boiler

Get a Quote

Boiler Feed Water Pressure Regulators

Boiler feed water pressure regulators are designed for use in commercial and residential hydronic heating systems to fill the boiler and piping system with water and maintain continuous pressure. Certain valve types also provide make-up water to the system and prevent backflow when supply pressure falls below system pressure.

Get a Quote

Hydrolevel 4566 VXT120 Automatic Water Feeder for steam

The best boilers to keep you warm in 2021 - Confused.com

Get a Quote

Automatic water feeder going bad? - DoItYourself.com

Jun 22, 2011 · Boilers - Home Heating Steam and Hot Water Systems - Automatic water feeder going bad? - Last winter I had my boiler system bled because of air in the system. The tech told me that there was the possibility of my automatic water feeder/water pressure regulator going bad because the water valve on top would not stay on

Get a Quote

Low Price 20t oil fired Boiler Lithuania

Ferroli is the major boiler producer in Italy and one of the major producers in Europe thanks to its complete and Baltur Boilers and Burners. Baltur are manufacturers of oil and gas burners and boilers. The boilers available are the MC and MCS models. Click Weishaupt Burners. As the agents for Baltur burners in Ireland, we carry an . Learn More

Get a Quote

Programmable Water Feeder for PROGRAMMABLE FEED …

Programmable Water Feeder for Steam Boilers 24VACOperatingVoltage PatentPending INSTALLATION ModelVXT-24 WARNING –To preventelectrical shockorequipment damage,power

Get a Quote

Steam boiler water feeder problem - HVAC-Talk

Jan 07, 2010 · Steam boiler water feeder problem. I have a Weil Mclain gas steam boiler (~1992-1993). After I purchased the house the automatic water feeder never worked. (automatic feeding function, manual push-button feed works fine). In the past I normally manual fed once every two weeks. But starting from last winter I had to put water more and more

Get a Quote

Related Information